PUMP TESTING LABORATORY
DELTA's
pump testing laboratory and its instrumentation matches or exceeds
the requirements of the American National Standard for Vertical
Pump Tests.
|
- Maximum
pump diameter capacity: 400 mm (16 inches).
- Tank
water volume: 35 m3 (9250 gallons).
- Tank
depth: 2.5 meters (8.2 feet).
- Flow
measurement: Differential pressure venturi type flow meter.
- Differential
pressure measurement: Electronic differential pressure sensor.
- Head
measurement: Electronic pressure sensor.
- Power
transmission: The pumps tested are directly coupled to vertical
hollow shaft electric motors.
- Torque
and speed measurement: Torque and speed sensor are directly
mounted on the pumps shaft for accurate power absorbed by the
bowl.
- Speed
control: Variable frequency drive, 0-100% of nominal speed
of the electric motor used.
- Head
regulation: Butterfly valve in discharge line.
- Cavitation:
Impingent cavitation can be accurately predicted by varying
the water level in the test tank by the use of a parallel water
transfer tank.

|
|